ewp

Wall Frame Tie-down Specification
|, ,
A complete solution for N2 wind – sheet roof - studs @ 450 c/c – trusses @ 600 c/c – SINGLE storey
Read more
QuikStick™ Rafter And Truss Fastening System
|, , ,
QuikStick™ Rafter And Truss Fastening System
Read more
MPP21 – Baubuche Intercultural Screen – Apr 2020
|
Hot off the press and only completed a week ago, Meyer Timber is proud to have worked with Lipman to supply Baubuche screening for a common area at Macquarie University. The project involved supply of 68 main blades which we 8.4m long, 600mm wide and...
Read more
Points to minimise the potential of Floor Squeaks
|, ,
POINTS TO MINIMISE THE POTENTIAL OF FLOOR SQUEAKS
Read more
Durability of Meyer Timber Engineered Wood Products Including LVL, I-joist and Glulam
|, ,
Untreated Engineered Wood Products (EWP) are suitable for use as structural members in protected, dry environments. They can also be impregnated with chemicals to increase their durability against various hazards. The hazard levels as defined in AS/NZS 1604 (and AS1684) are shown...
Read more
How to deal with Construction Loads
|, ,
November 2019 Construction loads can be defined as those loads imposed on a partially completed structure during and as a result of the construction process. These loads may include, but are not limited to, materials, personnel, and equipment placed onto a structure which has not...
Read more
Alternative fixing methods for Meyer Timber brackets
|, ,
Numerous brackets supplied by Meyer Timber are supplied with 3.75Øx35mm long nails for fixing. This is a minimum requirement as noted in the installation guide but it does not preclude the use of alternate connectors. This technical note outlines other suitable connectors that may be...
Read more
CCN64 Collated Connector Nailer
|,
Save time and money with fast connector nailing! Helps with the correct installation of connectors • Faster than traditional hand nailing • Nail tip protudes to easily locate connector hole • Multi-blow action hammers in, and helps prevent the nail from being overdriven • Compact...
Read more
meyJOIST Installation Reference Sheet
|, ,
The meyJOIST Install Reference Sheet contains common requirements for meyJOIST floor system installation used in houses. For detailed design or items not included, the meyJOIST Product Manual should be consulted by scanning the QR Code over the page, or at www.meyertimber.com.au BASIC REQUIREMENTS Minimum Distance...
Read more
SDS – H2-S Treated Laminated Veneer Lumber (LVL)
|,
Meyer Timber Chemwatch Hazard Alert Code: 1 Meyer Timber H2-S Treated Laminated Veneer Lumber (LVL) Chemwatch: 5292-76 Version No: 4.1.8.8 Safety Data Sheet according to WHS Regulations (Hazardous Chemicals) Amendment 2020 and ADG requirements Issue Date: 12/07/2021 Print Date: 14/07/2021 S.GHS.AUS.EN SECTION 1 Identification of...
Read more